CEPAC SITE SUMMARY REPORT
KLEENOIL Site Visist Reports & oil analysis for Qtr Dec20-Feb21
Client Site Visit & assessment CEPAC
By WWW.KLEENOIL.CO.UK
CUSTOMER DETAIL
INSPECTION PROCESS
CEPAC ROTHERHAM
Reports have pinpointed main characteristics of :
Visual install inspection – photographed
•
QUARTERLY FILTER CHANGE AND SAMPLING REPORT – 19/03/20 Following 3 months of filtration, KLEENOIL changed out the filter cartridges and took samples for independent laboratory analysis. Obviously sampling is taken at the end of the filtration interval and so represents the poorest level before fresh media is applied. • Our previous concerns of ‘wet’ oil are showing improvements simply through time of year – less condensation/temperature changes, so almost all the results are better in moisture levels.
Environment
•
Operating pressure
•
Visual oil condition
•
• Further comment And we have identified each report as Good Caution Needs attention
•
We would like to do a secondary, complimentary filter change and resample on the-
REPORT COMMENTS BUNDLE BREAKER - GOOD
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• KLEENOIL have done several rectifications on previous visits to ensure unit working - now the improvement on the particle count is significant and shows the unit has been operating correctly.
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
19/17/15
SAMPLED 23/06/20
17/16/13 improved
SAMPLED 02/10/20
17/16/13 STABLE
17/15/13 STABLE
SAMPLED 24/02/21
REPORT COMMENTS ACUSTACK 1 AND 2 - GOOD
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• Both units operating well in a hot but clean environment.
Unit checked & nothing to report
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD
CAUTION
ACTION
BASELINE 08/19
1=19/15/13 2= /
We took a 2 nd sample the following week to check acustack 1 and all ok Both reasonable – A2 is a little wet but current service will have addressed this.
SAMPLED 23/06/20
2=18/16/13 1 ST SAMPLE
1=19/16/13 - THE SAMPLE WAS WET – WE SUSPECT FROM A NEW OIL TOP UP – AND SO RECOMMEND USING FILTER RIG TO CLEAN AS TRANSFERING IN FUTURE
SAMPLED 02/10/20
A1=18/15/12 A2=20/17/14
SAMPLED 24/02/21
A1=18/16/14 A2=20/18/15
A1= STABLE A2= STABLE
REPORT COMMENTS LPD 1 – VERY GOOD
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• Unit operating well in a moist air environment.
Unit checked & nothing to report
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
19/17/15
SAMPLED 23/06/20
18/16/14 improved
SAMPLED 02/10/20
15/13/10 improved
16/14/12 Slightly down
SAMPLED 24/02/21
REPORT COMMENTS BALER 1, 2 AND 3
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• All 3 Units running off the same feed.
• Unit checked & nothing to report on 1 & 3 – sample from 2 needs redoing as found fibres
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
ACTION
CAUTION
GOOD
BASELINE 08/19
1 = 22/19/16 2 = 18/17/14 3 = 21/19/16
SAMPLED 23/06/20
1 = 20/18/15 2 = 17/15/12 3 = 18/16/14 1 & 2 have significant improvement 1-20/19/15 -STABLE 3=17/16/13 - IMPROVED
All good
SAMPLED 02/10/20
2= RESAMPLE?
SAMPLED 24/02/21
1=19/16/13 3=17/15/13 Both improved
2= RESAMPLE? Fibre in oil
REPORT COMMENTS FILTER PRESS
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
Unit checked & nothing to report
•
• Operating in a cold damp environment
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
22/20/17
SAMPLED 23/06/20 20/18/16 improved
SAMPLED 02/10/20
22/21/19
CHANGE & RESAMPLE
17/14/11 Improved
SAMPLED 24/02/21
REPORT COMMENTS PALMASTER 1 and 2
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
Unit checked & nothing to report
•
Environment warm and dry
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
CAUTION ACTION
GOOD
BASELINE 08/19
1 = 19/15/12 2 = 19/16/13
SAMPLED 23/06/20 1 = 18/16/14 2 = 17/15/12 2 = Improved
1 = slight downturn but still very clean
SAMPLED 02/10/20
1 = 16/14/12 2 = 16/15/13 BOTH IMPROVED SIGNIFICANTLY
SAMPLED 24/02/21
1=20/18/16 SLIGHT DOWNTURN 2=16/15/13 STABLE
REPORT COMMENTS
PREFEEDERS 1 TO 5
OIL SAMPLE RESULTS
ISO CODE
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis • All are stand alone hydraulic units with the same feed point
CAUTION ACTION
GOOD
BASELINE 08/19
1 = 19/15/12 2 = / 3 = 18/15/12 4 = 21/17/12 5 = 20/17/14 1 = 16/14/11 2 = 22/19/16 3 = 17/15/13 4 = 18/16/13 5 = 18/16/15 All Improved
Units checked
•
• Attending – Jonathan Brough – Kleenoil
SAMPLED 23/06/20
• On prefeeder 2 – Although clean ; Sampling indicates high iron which could be down to pump wear so we advise a check.
SAMPLED 02/10/20
1 = 18/16/14 SLIGHT DECREASE 2 = IMPROVEMENT 3 = 17/15/12 IMPROVEMENT 4 = 18/16/14 SLIGHT DECREASE 5 = 15/13/11 VERY IMPROVED 1 = 15/13/11 2 = 19/17/14 3 = 15/14/11 4 = 17/15/12 All Improved 5 = 16/15/12 Slight decrease but good
SAMPLED 24/02/21
REPORT COMMENTS
Corrugators 11, 9, 8, 6 and 5
ISO CODE
OIL SAMPLE RESULTS
CAUTION
ACTI ON
GOOD
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis • All units are mounted identically with the same feed point • Units checked – C11 oil was hot & smelt burnt but results were fair. Operator has been alerted.
BASELINE 08/19
11 = 22/19/14 9 = 23/21/16 8 = 20/16/14 6 = 21/17/14 5 = 21/17/15 11 = 17/15/12 9 = 21/17/13 8 = 17/16/13 6 = 17/14/11 5 = 16/14/11 All Improved
SAMPLED 23/06/20
Environment dry and clean
•
• Attending – Jonathan Brough - Kleenoil
SAMPLED 02/10/20
11 = 18/16/13 SLIGHT DECREASE 9 = 20/17/15 IMPROVED 8 = 17/15/13 IMPROVED
6 = 18/17/15 SLIGHT DECREASE 5 = 18/16/13 SLIGHT DECREASE
C11 RUNNING/ SMELLS HOT – OPERATOER ALERTED
SAMPLED 24/02/21
11 = 21/18/14 improved 9 = 18/16/14 improved 8 = 17/15/13 stable 6 = 19/18/15 improved 5 = 18/16/13 stable
REPORT COMMENTS CORRUGATOR 1
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• Unit operating well with good feed point
Environment clean
•
No leaks or problems reported
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
CAUTION ACTION
GOOD
BASELINE 08/19
17/15/13
SAMPLED 23/06/20
19/17/13 Slight downturn but still good
SAMPLED 02/10/20
18/16/14 IMPROVED
16/14/11 IMPROVED
SAMPLED 24/02/21
REPORT COMMENTS CORRUGATOR 2
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
Unit checked & nothing to report
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
18/16/14
SAMPLED 23/06/20
17/15/13 improved
SAMPLED 02/10/20
18/16/13 SLIGHT DECREASE
19/17/14 SLIGHT DECREASE
SAMPLED 24/02/21
REPORT COMMENTS CORRUGATOR 7
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
No issues reported.
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
22/19/15
SAMPLED 23/06/20
22/20/17 improved
SAMPLED 02/10/20
20/16/13 improved
20/19/16 DOWN
SAMPLED 24/03/21
REPORT COMMENTS CORRUGATOR 3/4 - OVEN
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
Environment hot
•
Unit checked & nothing to report
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD CAUTION ACTION
BASELINE 08/19
22/20/17
SAMPLED 23/06/20
20/16/12 improved
SAMPLED 17/10/20
20/18/15 poor
20/18/15 STABLE
SAMPLED 24/02/21
REPORT COMMENTS CORRUGATOR 10
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
Unit checked & nothing to report
•
• Attending – Jonathan Brough – Kleenoil
• Sampling indicates high iron which could be down to pump wear so we advise a check
ISO CODE
OIL SAMPLE RESULTS
GOOD
CAUTION ACTIO N
BASELINE 08/19
24/21/17
SAMPLED 23/06/20
20/18/14 improved
SAMPLED 17/10/20
22/19/16 poor
20/17/13 IMPROVED
SAMPLED 24/02/21
Future recommendations
KLEENOIL offer suggestions moving forward from observations made on the visit :
• There could be more guarding on the machines to protect hoses and handles
• Filler caps need to be checked to be an effective seal in preventing dust entering the oil tanks
• CORRUGATOR 4 – OVEN – possibly look at installing an oil cooler
• KLEENOIL will focus on machines with poor oil sample results, to work and bringing the levels into specification through additional filter changes and machine checks. • KLEENOIL will continually monitor all the units through the standard quarterly inspections and keep CEPEC updated