KLEENOIL Engine Applications

Generic Installation Guide Kleenoil LDU9768KU16 Bypass Oil Filtration Unit

Please note: This is a general reference guide. Specific applications may vary. Please consult KLEENOIL for installation support. Safety Precautions Before Instaling Ensure the machine/engine is fully shut down and cooled before beginning work. Wear appropriate PPE (gloves, eye protection). Ensure the work area is clean and free of contaminants . Dispose of any old fluid or filters according to local regulations.

What’s in the Box

Tools & Materials Required Spanners/wrenches Pipe cutter (if required) Drill and mounting hardware Oil catch tray & cleaning rags

1 x LDU9768KU16 Kleenoil Bypass Filter Unit 1 x Mounting Bracket (pre-drilled) 1 x Replacement Cartridge (installed) 1 x Installation & User Guide (optional digital copy)

You will need to source 2 x Hydraulic hoses- Feed/Return (recommended: ¼ RTI INLET / 3/8 RTI RETURN ) 1 x Fittings Kit (check compatibility with engine/system ports) (pipe fittings can be reusable on engines / we advise swaged from your local hydraulics shop once you have established pipe lengths required) Installation Steps Do not use the LDU9768KU16 Kleenoil system for Hydraulic lines/applications without the KLEENOIL PRV ( pressure reducing/pressure relief valve ) Step 1: Choose Mounting Location Select a solid, vibration-free location close to the engine or hydraulic reservoir. The filter should be upright and vertical for best cartridge performance. Ensure easy access for future servicing (cartridge changes). Tip: Keep hoses as short and straight as possible to maximize efficiency. Step 2: Mount the Filter Unit Use the provided bracket to secure the unit.

Bolt onto a chassis rail, engine bay panel, or machine frame . Ensure the bracket supports the weight of a fully saturated filter.