Portable Filtration MS Range

RESULTS ACHIEVED

Before vs After Filtration

Water : 764 ppm → 747 ppm (slight reduction; bound water remained, requiring extended filtration). TAN : 0.90 → 0.83 (stabilised acidity). Particles : o 4 µm: 16,385 → 2,393 ( ↓ 85%) o 6 µm: 3,162 → 584 ( ↓ 82%) o 14 µm: 72 → 28 ( ↓ 61%) ISO Cleanliness : Improved from 21/19/13 → 18/16/12 . Wear Metals : o Iron reduced (3 → 2 ppm). o Copper stable (4 ppm). o Lead reduced (1 ppm → undetectable)

Figure 1 brand new oil sample