Report Example - plastics

A X - Immediate Action C - Action B - Monitor A - No Action

NB1300T

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

Make Model

HYDRAULICS UNKNOWN

Address

SHERBURN IN ELMET,WEST YORKSHIRE FENTON LANE,

Location

30/07/2025

Sample Date

Job No

HYDRAULIC SYSTEM Unknown unknown

Component Lubricant

Received Date

01/08/2025

Ian Burton

Interpreted By

Reported Date

07/08/2025

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1 551278154 01/05/2025

Previous #2

Lab No

- - - - - - - - -

- - - - - - - - -

552138329 30/07/2025

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

30

0.00

0.00

V40

20

Fluid Changed Filter Changed

No No

No No

10

Lubricant Label No

Unknown

Unknown

0

-

-

Prev #1

Current

Physical Tests Viscosity at 100 C Viscosity at 40 C

Particles

ASTM D7279-14 ASTM D7279-14

cSt cSt

7.2

7.3

800

46.4 115

49.3 108

700

Viscosity Index

ASTM D2270 ASTM D6304 ASTM D6304

Integer

600

Water

ppm

26

22

500

14 4 6 PQI

Water (% Wt) Oil Condition

% Wt.

0.0026

0.0022

400

300

Total Acid Number

ASTM D8045

mg/g KOH

0.38

0.54

200

Particles

100

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 In-House

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

7 2 1

- - - - - -

0

Prev #1

Current

Oil Contaminants

1

4µ 6µ

775 167

0.8

70µ

0

ISO Code PQ Index

Code

17/15/10

OUT OF RANGE

0.6

Na Si

N/A

3

4

0.4

Oil Contaminants

Potassium

ppm ppm ppm ppm ppm ppm ppm ppm ppm PPM ppm ppm

0 1 0

0 0 0

0.2

Silicon Sodium

0

Prev #1

Current

Wear Metals Aluminium

0

0

Chromium

0.0

0.0

Copper

4 1 0 0 0 0

3 1 0 0 0 0

Iron

Lead

Nickel Silver

0.1

0.0

Tin

Titanium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2