2.0 Work Carried out

The chronology of events are detailed below.

Day

Comments

 Site induction and meeting with site personnel.  MS4 installed on 10MW turbine and started at 1300hrs  Sample 1 taken from 10MW Standard filters  Rig switched off at 1900hrs  MS4 moved to 5MW turbine Standard filters  MS6 moved to 10MW turbine Standard filters

Monday

Tuesday

 Rigs switched on at 0700hrs  Sample 1 taken from 5MW  Rigs switched off at 1900hrs

 MS4 and MS6 turned on at 0700hrs  Filter changed to 1 micron filters  Photograph of dirty filters taken. (See Appendix A&B)  5MW tank agitated  Sample 2 taken from 5MW and 10MW turbine  Sample taken of clean oil  Particle counter fitted to 10MW rig. NAS 6 achieved. (See Appendix B)  Rig switched off at 1900hrs  MS4 and MS6 turned on at 0700hrs  Requested to transfer 400lts of oil into 10MW turbine.  10MW tank agitated.  Sample 3 taken from 5MW and 10MW turbine  Particle counter fitted to 5MW rig. NAS 5 achieved. (see Appendix A).  Rig switched off at 1900hrs  Sample taken from 5MW and 10MW tank.

Wednesday

Thursday

Kleenoil Bypass Filtration Ltd Fenton Lane, Sherburn In Elmet, LS25 6EZ. www.kleenoil.co.uk Tel 01977 682810 Fax 01977 685457