TRIVENI TURBINE OIL CLEANING
the original since 1976
3.2 10MW Turbine
The results from the samples taken from the 10MW turbine are shown in the table below.
From the above, the following can be said: -
The Kleenoil unit polished the oil from 22/20/15 down to 21/18/13 (final tank sample) over the 4 day period. The reading of 21/18/13 is equivalent to a NAS 6. While on site the particle counter was fitted to the rig. This gave a reading of NAS 6. This confirms that the particle counter was operating correctly.
Conclusions
Kleenoil polished the oil to NAS 6, which meets the customers requirements of NAS 6.