UPG - MACHINE 143-24

KLEENOIL Laboratory results

FILTRATION SITE VISIT REPORT

NAME / SITE

- UPG

Site

-

CONTACT - KLEENOIL ENGINEER - Jonathan

TEL - 07775 641250

MACHINE NUMBER : 143

SUMMARISED UPDATE

SDFC1888KF85 Filter change

Significant improvement—GOOD

Dry

INLINE BY - PASS FILTRATION SYSTEM

wear - stable

6mthly testing

Chemistry - stable

LAST CHANGE

07/07/24

NEXT CHANGE DUE

30/12/24

VISIT REPORT

Site

UPG

Date of previous visit Date

05/07/2024

Contacts Machine

24-143

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

12.00

25000

G A G

10.00

20000

8.00

15000

6.00

10000

Out of barrel

4.00

5000

2.00

0.00

0

4 6 14

ISO 17/14/11 NAS 6

Traffic Light

Moisture

05/07/2 4

30/11

500

11/23/2 022

Serious Good Caution

11/2

05/0

30/1

Comments/Suggestions Significantly cleaner - v good

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

A X - Immediate Action C - Action B - Monitor A - No Action

143 UPG 143

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN UPG

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

05/07/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

11/07/2024

Ian Burton

Interpreted By

Reported Date

17/07/2024

Wear Metals

Wear Metals Vanadium

ASTM D5185-97

ppm

0

1

Additives Barium Boron Calcium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm

1 0

0.8

0.6

Cr Cu Fe Ni Pb

45

Magnesium Molybdenum Phosphorus

0 0

0.4

0.2

327 417

Zinc

0

Prev #2

Prev #1

Current

A - No Action A

Diagnosis: THE PARTICLE COUNT IS WITHIN TARGET (ISO 21/18/15) AND THE WEAR READINGS GIVE US NO CAUSE FOR CONCERN. WE WILL OBSERVE THE NEXT SCHEDULED SAMPLE BEFORE MAKING FURTHER COMMENTS.

X - Immediate Action C - Action B - Monitor

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

A X - Immediate Action C - Action B - Monitor A - No Action

143 UPG 143

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN UPG

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

05/07/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

11/07/2024

Ian Burton

Interpreted By

Reported Date

17/07/2024

Sample Details

Test Method

Units

Current Result

Previous #1

Previous #2

Physical Tests

Lab No

- - - - - - - - -

- - - - - - - - -

541938240 05/07/2024

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

30

0.00

V40

20

Fluid Changed Filter Changed

No No

10

Lubricant Label No

Unknown

0

-

Prev #2

Prev #1

Current

Physical Tests Viscosity at 100 C Viscosity at 40 C

Particles

ASTM D7279-14 ASTM D7279-14

cSt cSt cSt

7.2

18K

46.7 114

16K

Viscosity Index

ASTM D2270 ASTM D6304 ASTM D6304

14K

Water

ppm

30

12K

14 4 6 PQI

10K

Water (% Wt) Oil Condition

% Wt.

0.0030

8K

6K

Total Acid Number

ASTM D8045

mg/g KOH

0.11

4K

Particles

2K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 In-House

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

16

0K

Prev #2

Prev #1

Current

5 1

Oil Contaminants

5

4µ 6µ

657 148

4

70µ

0

ISO Code PQ Index

Code

17/14/11

3

Na Si

N/A

5

2

Oil Contaminants

Potassium

ppm ppm ppm ppm ppm ppm ppm ppm ppm PPM ppm ppm

1 0 0

1

Silicon Sodium

0

Prev #2

Prev #1

Current

Wear Metals Aluminium

0

Chromium

0.0

Copper

1 0 0 0 0 0

Iron

Lead

Nickel Silver

0.0

Tin

Titanium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

C X - Immediate Action C - Action B - Monitor A - No Action

143 UPG 143

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN UPG

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

30/11/2023

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

08/12/2023

Ian Burton

Interpreted By

Reported Date

12/12/2023

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1 531511606 24/05/2023

Previous #2

Lab No

- - - - - - - - -

- - - - - - - - -

533424663 30/11/2023

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

30

0.00

0.00

V40

20

Fluid Changed Filter Changed

No No

No No

10

Lubricant Label No

Unknown

Unknown

0

-

-

Prev #1

Current

Physical Tests Viscosity at 40 C

Particles

ASTM D7279-14

cSt

35.3

47.4

18K

Particles

16K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

324

53 12

14K

32

12K

14 4 6 PQI

3

1

10K

8K

4µ 6µ

16287

2530

6K

4776

520

4K

70µ

0

0

2K

ISO Code PQ Index

Code

21/19/16

19/16/13

0K

Prev #1

Current

In-House

N/A

3

5

Oil Contaminants

Oil Contaminants

5

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

0 1 0

1 0 5

Silicon Sodium

4

Water

In-House

Pos/Neg

N

N

3

Na Si

Wear Metals

2

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm

0

0

0.0

0.0

1

Copper

1 0 0

1 0 0

0

Iron

Prev #1

Current

Lead

Nickel

0.1

0.0

Tin

0

0

Additives

Barium Boron Calcium

0 2

0 0

46

42

Magnesium Molybdenum Phosphorus

0 0

0 0

343

322

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

C X - Immediate Action C - Action B - Monitor A - No Action

143 UPG 143

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN UPG

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

30/11/2023

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

08/12/2023

Ian Burton

Interpreted By

Reported Date

12/12/2023

Wear Metals

Additives

Zinc

ASTM D5185-97

ppm

420

418

1

Diagnosis: ACTION REQUIRED! THE WEAR METALS GIVE US NO CAUSE FOR CONCERN. HOWEVER, THE PARTICLE COUNT IS RATHER HIGHER THAN TARGET (ISO 21/18/15). STEPS SHOULD BE TAKEN TO BRING THE PARTICLE COUNT BACK WITHIN TARGET.

A - No Action C

X - Immediate Action C - Action B - Monitor

0.8

0.6

Cr Cu Fe Ni Pb

0.4

0.2

0

Prev #1

Current

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

VISIT REPORT

Site

UPG

Date of previous visit

24/05/2023 30/11/2023

Date

Contacts Machine

24-143

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

12.00

25000

A G

10.00

20000

8.00

15000

6.00

10000

Out of barrel

4.00

5000

2.00

0.00

0

4 6 14

ISO 21/19/16 NAS10

Traffic Light

Moisture

30/11

11/23/2 022

500

Serious Good Caution

30/1

11/2

Comments/Suggestions Dirtier but wear and chemistry stabl so monitor into next change

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk