CEPAC SITE SUMMARY REPORT
REPORT COMMENTS ACUSTACK 1 AND 2 - GOOD
• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis
• Both units operating well in a hot but clean environment.
Unit checked & nothing to report
•
• Attending – Jonathan Brough - Kleenoil
ISO CODE
OIL SAMPLE RESULTS
GOOD
CAUTION
ACTION
BASELINE 08/19
1=19/15/13 2= /
We took a 2 nd sample the following week to check acustack 1 and all ok Both reasonable – A2 is a little wet but current service will have addressed this.
SAMPLED 23/06/20
2=18/16/13 1 ST SAMPLE
1=19/16/13 - THE SAMPLE WAS WET – WE SUSPECT FROM A NEW OIL TOP UP – AND SO RECOMMEND USING FILTER RIG TO CLEAN AS TRANSFERING IN FUTURE
SAMPLED 02/10/20
A1=18/15/12 A2=20/17/14
SAMPLED 24/02/21
A1=18/16/14 A2=20/18/15
A1= STABLE A2= STABLE