CEPAC SITE SUMMARY REPORT

REPORT COMMENTS LPD 1 – VERY GOOD

• KLEENOIL Filtration cartridge changed, and oil sample taken for independent laboratory analysis

• Unit operating well in a moist air environment.

Unit checked & nothing to report

• Attending – Jonathan Brough - Kleenoil

ISO CODE

OIL SAMPLE RESULTS

GOOD CAUTION ACTION

BASELINE 08/19

19/17/15

SAMPLED 23/06/20

18/16/14 improved

SAMPLED 02/10/20

15/13/10 improved

16/14/12 Slightly down

SAMPLED 24/02/21