EMR SILVERTOWN - METSO

KLEENOIL Condition monitoring - Laboratory reports

ISO CODE ; 19/16/12

SILVERTOWN FILTRATION & OIL SAMPLING SITE VISIT REPORT EUROPEAN METAL RECYCLING Your dedicated KLEENOIL Engineer contact details;

(was 19/17/11)

IMPROVED AGAIN –

SUMMARISED UPDATE

Jonathan Brough

• PARTICULATE: AS CLEAN AS NEW OIL

TEL -07775 641250

• CHEMISTRY:

STABLE

john@kleenoil.co.uk

• WEAR:

STABLE

Richard Paddock

• MOISTURE:

NOT REPORTABLE

TEL -07775 641247

ADVISE – this keeps improving - good

richard@kleenoil.co.uk

MACHINE DETAILS: METSO SHEAR

What do your colour codes indicate?

GREEN is GOOD – ISO 19/16/15 or better

EXISTING FILTRATION

AMBER is CAUTION - ISO 22/20/16 or worse

Pressure filter s

1 X SHR2600FD11

Air filtration

3 x SA13215

RED

is SERIOUS – ISO 24/23/18 or

By-pass filtration

-

worse; ACTION NEEDED

This latest change was done ; CURRENT CHANGE (Qtr3) We will contact site to arrange your NEXT CHANGE / SAMPLING DUE ; Around 17/01/25 (Qtr4) - 19/10/24

If you need any assistance between quarterly visits, please do not hesitate to contact us on the above numbers

or

through our office – TEL; 01977 682810 ; sales@kleenoil.co.uk

EMR VISIT REPORT

Site

Silvertown

Date of previous visit Date

17/10/2024

Contacts Machine

Metso

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

14

40000

G G R

35000

12

30000

10

Out of barrel

25000

8

20000

6

15000

4

10000

2

5000

0

0

Qtr2

Qtr4

Qtr2

Qtr2

Qtr4

Qtr2

4 6 14

Filters changed ISO 19/17/11 NAS 8

Traffic Light

Moisture

Qtr2

Qtr4

500

Qtr2

Serious Good Caution

Qtr4

Qtr2

Qtr2

Comments/Suggestions Better on larger particulate - finer has risen but not of concerning level ; top ups may not be same oils but not an issue on this type of machinery

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

A X - Immediate Action C - Action B - Monitor A - No Action

EMR SILVERTOWN METSO SHEAR - EMR SILVERTOWN

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN EMR SILVERTOWN

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

17/10/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 32

Received Date

18/10/2024

Ian Burton

Interpreted By

Reported Date

21/10/2024

Sample Details

Test Method

Units

Current Result

Previous #1 541298138 30/04/2024

Previous #2

Physical Tests

Lab No

- - - - - - - - -

- - - - - - - - -

542928917 17/10/2024

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

30

0.00

0.00

V40

20

Fluid Changed Filter Changed

No No

No No

10

Lubricant Label No

Unknown

Unknown

0

-

-

Prev #4 Prev #3 Prev #2 Prev #1 Current

Physical Tests Viscosity at 100 C Viscosity at 40 C

Particles

ASTM D7279-14 ASTM D7279-14

cSt cSt cSt

6.1

28K

34.7 123

43.4

24K

Viscosity Index

ASTM D2270 ASTM D6304 ASTM D6304

20K

Water

ppm

19

74

16K

14 4 6 PQI

Water (% Wt) Oil Condition

% Wt.

0.0019

0.0074

12K

Total Acid Number

ASTM D8045

mg/g KOH

0.23

0.30

8K

Particles

4K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 In-House

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

19

137

0K

Prev #4 Prev #3 Prev #2 Prev #1 Current

6 2

33

Oil Contaminants

2

32

4µ 6µ

4122

2830

28

687

954

24

70µ

1

0

20

ISO Code PQ Index

Code

19/17/11

19/17/14

Na Si

16

N/A

7

33

12

Oil Contaminants

8

Potassium

ppm ppm ppm ppm ppm ppm ppm ppm ppm PPM ppm ppm

0 3 0

0

4

Silicon Sodium

25

0

0

Prev #4 Prev #3 Prev #2 Prev #1 Current

Wear Metals Aluminium

0

0

Chromium

0.0

0.0

Copper

0 0 0 0 0 0

0 0 0 0 0 0

Iron

Lead

Nickel Silver

0.0

0.0

Tin

Titanium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

A X - Immediate Action C - Action B - Monitor A - No Action

EMR SILVERTOWN METSO SHEAR - EMR SILVERTOWN

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN EMR SILVERTOWN

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

17/10/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 32

Received Date

18/10/2024

Ian Burton

Interpreted By

Reported Date

21/10/2024

Wear Metals

Wear Metals Vanadium

ASTM D5185-97

ppm

0

0

1

Additives Barium Boron Calcium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm

0 1

2 1

0.8

0.6

Cr Cu Fe Ni Pb

14

55

Magnesium Molybdenum Phosphorus

0 0

1 1

0.4

0.2

292 339

428 470

Zinc

0

Prev #4 Prev #3 Prev #2 Prev #1 Current

A - No Action A

Diagnosis: THE PARTICLE COUNT IS WITHIN TARGET (ISO 21/18/15) AND THE WEAR READINGS GIVE US NO CAUSE FOR CONCERN. WE WILL OBSERVE THE NEXT SCHEDULED SAMPLE BEFORE MAKING FURTHER COMMENTS.

X - Immediate Action C - Action B - Monitor

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

EMR VISIT REPORT

Site

Silvertown

Date of previous visit Date

30/04/2024

Contacts Machine

Metso

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

14

40000

G R G

35000

12

30000

10

Out of barrel

25000

8

20000

6

15000

4

10000

2

5000

0

0

Qtr4

Qtr2

4

Qtr4

Qtr2

4

4 6 14

Filters changed ISO 19/17/14 (NAS 9)

Traffic Light

Moisture

Qtr4

Qtr2

500

4

Serious Good Caution

Qtr2

4

Qtr4

Comments/Suggestions As clean as new oil with good chemistry

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

A X - Immediate Action C - Action B - Monitor A - No Action

EMR SILVERTOWN METSO SHEAR - EMR SILVERTOWN

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN EMR SILVERTOWN

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

30/04/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

08/05/2024

Ian Burton

Interpreted By

Reported Date

15/05/2024

Wear Metals

Additives

Barium Boron Calcium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm

2 1

1

0.8

55

Magnesium Molybdenum Phosphorus

1 1

0.6

Cr Cu Fe Ni Pb

428 470

0.4

Zinc

0.2

Diagnosis: THE PARTICLE COUNT IS WITHIN TARGET (ISO 21/18/15) AND THE WEAR READINGS GIVE US NO CAUSE FOR CONCERN. WE WILL OBSERVE THE NEXT SCHEDULED SAMPLE BEFORE MAKING FURTHER COMMENTS.

A - No Action A

X - Immediate Action C - Action B - Monitor

0

Prev #3

Prev #2

Prev #1

Current

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

A X - Immediate Action C - Action B - Monitor A - No Action

EMR SILVERTOWN METSO SHEAR - EMR SILVERTOWN

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN EMR SILVERTOWN

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

30/04/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

08/05/2024

Ian Burton

Interpreted By

Reported Date

15/05/2024

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1

Previous #2

Lab No

- - - - - - - - -

- - - - - - - - -

541298138 30/04/2024

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

30

0.00

V40

20

Fluid Changed Filter Changed

No No

10

Lubricant Label No

Unknown

0

-

Prev #3

Prev #2

Prev #1

Current

Physical Tests Viscosity at 40 C

Particles

ASTM D7279-14

cSt

43.4

28K

Water

ASTM D6304 ASTM D6304

ppm

74

24K

Water (% Wt) Oil Condition

% Wt.

0.0074

20K

16K

14 4 6 PQI

Total Acid Number

ASTM D8045

mg/g KOH

0.30

12K

Particles

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

137

8K

33

4K

2

0K

Prev #3

Prev #2

Prev #1

Current

4µ 6µ

2830

Oil Contaminants

954

32

70µ

0

28

ISO Code PQ Index

Code

19/17/14

24

In-House

N/A

33

20

Oil Contaminants

Na Si

16

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

0

12

Silicon Sodium

25

8

0

4

Water

In-House

Pos/Neg

N

0

Wear Metals

Prev #3

Prev #2

Prev #1

Current

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm PPM ppm ppm ppm

0

0.0

Copper

0 0 0 0 0 0 0

Iron

Lead

Nickel Silver

0.0

Tin

Titanium Vanadium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

EMR VISIT REPORT

Site

Silvertown

Date of previous visit Date

19/11/2023

Contacts Machine

Metso

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

14

40000

R G A

35000

12

30000

10

Out of barrel

25000

8

20000

6

15000

4

10000

2

5000

0

0

Qtr2

4

3

Qtr2

4

3

4 6 14

Filters changed ISO 22/20/16 NAS12

Traffic Light

Moisture

Qtr2

4

500

3

Serious Good Caution

4

3

Qtr2

Comments/Suggestions Dirtier after having been so good - current filter changes should help to improve this as a qtr change was previously missed and we will monitor into next qtr - wear and chemistry are relatively stable.

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

B X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

Make Model

Address

SHERBURN IN ELMET,WEST YORKSHIRE FENTON LANE,

Location

19/11/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

22/11/2023

Unknown 46

Samad Ali

Interpreted By

Reported Date

24/11/2023

Wear Metals

Diagnosis: THE PARTICLE COUNT HAS DETERIORATED BADLY (TARGET ISO 21/18/15) BUT WEAR METALS REMAIN STABLE. WE SUSPECT POSSIBLE (UNINTENTIONAL) SAMPLE CONTAMINATION SO WE'LL OBSERVE THE NEXT SCHEDULED SAMPLE BEFORE MAKING FURTHER COMMENTS.

A - No Action B

X - Immediate Action C - Action B - Monitor

1

0.8

0.6

Cr Cu Fe Ni Pb

0.4

0.2

0

Prev #2

Prev #1

Current

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

B X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

Make Model

Address

SHERBURN IN ELMET,WEST YORKSHIRE FENTON LANE,

Location

19/11/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

22/11/2023

Unknown 46

Samad Ali

Interpreted By

Reported Date

24/11/2023

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1 531511624 23/05/2023

Previous #2 530462873 09/02/2023

Lab No

- - - - - - - -

- - - - - - - -

533262973 19/11/2023

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

0 0

30

0.00

0.00

0.00

V40

20

Fluid Changed Filter Changed

No No

No No

No No

10

Lubricant

Unknown

Unknown

Unknown

0

Physical Tests Viscosity at 40 C

Prev #2

Prev #1

Current

ASTM D7279-14

cSt

42.8

47.0

44.1

Particles

Particles

28K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

494

32

355

24K

34

4 1

67

20K

1

9

16K

14 4 6 PQI

4µ 6µ

27095

2451

17714

9592

434

4878

12K

70µ

0

0

2

8K

ISO Code PQ Index

Code

22/20/16

18/16/12

21/19/16

4K

In-House

N/A

5

5

3

0K

Prev #2

Prev #1

Current

Oil Contaminants

Oil Contaminants

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

1

1

0

32

Silicon Sodium

27

26

29

28

0

5

2

24

Water

In-House

Pos/Neg

N

N

N

20

Wear Metals

Na Si

16

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm

0

0

0

12

0.0

0.0

0.1

8

Copper

0 0 0

1 0 0

0 1 0

4

Iron

0

Lead

Prev #2

Prev #1

Current

Nickel

0.1

0.0

0.0

Tin

0

0

0

Additives

Barium Boron Calcium

0 1

0 1

0 1

54

52

58

Magnesium Molybdenum Phosphorus

1 1

0 1

2 1

376 436

397 469

411 469

Zinc

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

EMR VISIT REPORT

Site

Silvertown 09/02/2023 01/06/2023

Date of previous visit

Date

Contacts Machine

Metso

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

12

25000

G A

10

20000

Out of barrel

8

15000

6

10000

4

5000

2

0

0

4

3

4

3

4 6 14

Filters changed iso 23/05/23 nas 7

Traffic Light

Moisture

4

3

500

Serious Good Caution

3

4

Comments/Suggestions SIGNIFICANTLY CLEANER - ISO Rated to new oil standard

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

A X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL

Customer Name

Make Model

Address

LEEDS,WEST YORKSHIRE FENTON LANE,

Location

23/05/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

26/05/2023

Unknown 46

Francis Kapondoro

Interpreted By

Reported Date

01/06/2023

Wear Metals

Diagnosis: THE PARTICLE COUNT IS WITHIN TARGET (ISO 21/18/15) AND THE WEAR READINGS GIVE US NO CAUSE FOR CONCERN. WE WILL OBSERVE THE NEXT SCHEDULED SAMPLE BEFORE MAKING FURTHER COMMENTS.

A - No Action A

X - Immediate Action C - Action B - Monitor

1

0.8

0.6

Cr Cu Fe Ni Pb

0.4

0.2

0

Prev #1

Current

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

A X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL

Customer Name

Make Model

Address

LEEDS,WEST YORKSHIRE FENTON LANE,

Location

23/05/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

26/05/2023

Unknown 46

Francis Kapondoro

Interpreted By

Reported Date

01/06/2023

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1 530462873 09/02/2023

Previous #2

Lab No

- - - - - - - -

- - - - - - - -

531511624 23/05/2023

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

30

0.00

0.00

V40

20

Fluid Changed Filter Changed

No No

No No

10

Lubricant

Unknown

Unknown

0

Physical Tests Viscosity at 40 C

Prev #1

Current

ASTM D7279-14

cSt

47.0

44.1

Particles

Particles

18K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

32

355

16K

4 1

67

14K

9

12K

14 4 6 PQI

4µ 6µ

2451

17714

10K

8K

434

4878

6K

70µ

0

2

4K

ISO Code PQ Index

Code

18/16/12

21/19/16

2K

In-House

N/A

5

3

0K

Prev #1

Current

Oil Contaminants

Oil Contaminants

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

1

0

32

Silicon Sodium

26

29

28

5

2

24

Water

In-House

Pos/Neg

N

N

20

Wear Metals

Na Si

16

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm

0

0

12

0.0

0.1

8

Copper

1 0 0

0 1 0

4

Iron

0

Lead

Prev #1

Current

Nickel

0.0

0.0

Tin

0

0

Additives

Barium Boron Calcium

0 1

0 1

52

58

Magnesium Molybdenum Phosphorus

0 1

2 1

397 469

411 469

Zinc

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

EMR VISIT REPORT

Site

Silvertown

Date of previous visit Date

09/02/2023

Contacts Machine

Metso

`

Site Induction

Y Y Y Y

Isolation procedure completed

Padlock issued

Debrief

NAS CODE

PARTICLE COUNT

12

25000

A

10

20000

Out of barrel

8

15000

6

10000

4

5000

2

0

0

3

3

4 6 14

Filters changed iso 21/19/16 nas11

Traffic Light

Moisture

3

500

Serious Good Caution

3

Comments/Suggestions FIRST SAMPLE - not great but wear and chemistry are acceptable so we will monitor into next qtr for a comparison

KLEENOIL UK LIMITED, FENTON LANE, LEEDS LS25 6EZ  01977 682810  sales@kleenoil.co.uk

C X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL

Customer Name

Make Model

Address

LEEDS,WEST YORKSHIRE KLEEN OIL HOUSE,15 HIGH STREET,SOUTH MILFORD

Location

09/02/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

15/02/2023

Unknown 46

Ian Burton

Interpreted By

Reported Date

17/02/2023

Diagnosis: ACTION REQUIRED! THE WEAR METALS GIVE US NO CAUSE FOR CONCERN BUT THE PARTICLE COUNT IS MUCH HIGHER THAN TARGET (ISO 21/18/15). ASSUMING THIS IS A REPRESENTATIVE SAMPLE THEN STEPS NEED TO BE TAKEN TO IMPROVE THE PARTICLE COUNT READING. THE FILTRATION ELEMENT OF THIS SYSTEM NEEDS TO BE CONFIRMED AND UP-GRADED IF AN ALTERNATIVE IS AVAILABLE.

A - No Action C

X - Immediate Action C - Action B - Monitor

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 2 of 2

C X - Immediate Action C - Action B - Monitor A - No Action

HYDRAULICS UNKNOWN EMR SILVERTOWN EMR SILVERTOWN METSO

Unit Number Serial Number

KLEENOIL

Customer Name

Make Model

Address

LEEDS,WEST YORKSHIRE KLEEN OIL HOUSE,15 HIGH STREET,SOUTH MILFORD

Location

09/02/2023

Sample Date

Job No

HYDRAULIC SYSTEM

Component Lubricant

Received Date

15/02/2023

Unknown 46

Ian Burton

Interpreted By

Reported Date

17/02/2023

Sample Details

Test Method

Units

Current Result

Previous #1

Previous #2

Lab No

- - - - - - - -

- - - - - - - -

530462873 09/02/2023

Sample Date

Meter Hrs Fluid Hrs Oil Added

0 0

0.00

Fluid Changed Filter Changed

No No

Lubricant

Unknown

Physical Tests Viscosity at 40 C

ASTM D7279-14

cSt

44.1

Particles

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

355

67

9

4µ 6µ

17714

4878

70µ

2

ISO Code PQ Index

Code

21/19/16

In-House

N/A

3

Oil Contaminants

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

0

Silicon Sodium

29

2

Water

In-House

Pos/Neg

N

Wear Metals

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm

0

0.1

Copper

0 1 0

Iron

Lead

Nickel

0.0

Tin

0

Additives

Barium Boron Calcium

0 1

58

Magnesium Molybdenum Phosphorus

2 1

411 469

Zinc

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

Guide to Contamination Standards

This guidebook is aimed at engineers, technicians and quality control personnel involved in contamination control. Its purpose is to make available accepted and widely-used cleanliness specification levels for liquid samples. The tables in this guide allow users of using automatic portable particle counters to see the relationship between raw particle counts at various sizes and the reporting code numbers of various contamination standards. A NOTE ON THE FIGURES USED Note that some of the table entries are defined as cumulative counts (e.g. “> 6µm”) and others are defined as differential counts (e.g. 6–14µm”). Instances of particle sizes given as “µm” refer to ACFTD (i.e. Air Cleaner Fine Test Dust) distributions. Instances of particle sizes given as “µm(c)” refer to MTD (i.e. ISO Medium Test Dust) distributions. All standards are in counts per volume, and provide easy methods for converting particle counts into limits that are simple to interpret. By noting the requirements of the standard, particle counts can be accurately converted to contamination levels.

67

ISO Cleanliness Code Hydraulic Fluid Contamination

Number of particles per ml More than

ISO code number

Up to and including

22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07

20,000 10,000

40,000 20,000 10,000

5,000 2,500 1,300

5,000 2,500 1,300

640 320 160

640 320 160

80 40 20 10

80 40 20 10

5

2.5 1.3

5

2.5 1.3

0.64

68

Suggested Acceptable Contamination Codes

ISO code numbers 23 / 21 / 17 20 / 18 / 15

Typical components

Type of system

Sensitivity

Low pressure systems with large clearances Typical cleanliness of new hydraulic oil straight from the manufacturer. Low pressure heavy industrial systems or applications where long-life is not critical General machinery and mobile systems Medium pressure, medium capacity World Wide Fuel Charter cleanliness standard for diesel fuel delivered from the filling station nozzle. Highly sophisticated systems and hydrostatic transmissions Performance servo and high Pressure long-life systems e.g. Aircraft machine tools, etc. Silt sensitive control system with very high reliability Laboratory or aerospace High quality reliable systems General machine requirements

Ram pumps

Low

Flow control valves Cylinders

Average

19 / 17 / 14

Gear pumps/motors Important

18 / 16 / 13

Injector valve and high pressure pumps/ motors Directional and pressure control valves

Critical

17 / 15 / 12

Proportional valves

Critical

16 / 14 / 11

Industrial servovalves Critical

15 / 13 / 09

High performance servovalves

Super critical

NOTE: The three figures of the ISO code numbers represent ISO level contamination grades for particles of >4µm(c), >6µm(c) and >14µm(c) respectively.

69

ISO/NAS/SAE Code Comparison Table The comparisons relate to particle count data only. To conform to any particular standard, reference should be made to the recommended experimental procedure. ISO/DIS 4406 BS 5540/4 codes Defence Std. 05/42 NAS 1638 SAE 749 Table A Table B 13 / 11 / 08 2 14 / 12 / 09 3 0 15 / 13 / 10 4 1 16 / 14 / 09 400F 16 / 14 / 11 5 2 17 / 15 / 09 400 17 / 15 / 10 800F 17 / 15 / 12 6 3 18 / 16 / 10 800 18 / 16 / 11 1300F 18 / 16 / 13 7 4 19 / 17 / 11 1300 2000 19 / 17 / 14 8 5 20 / 18 / 12 2000 20 / 18 / 13 4400F 20 / 18 / 15 9 6 21 / 19 / 13 4400 6300F 21 / 19 / 16 10 22 / 20 / 13 6300 22 / 20 / 17 11 23 / 21 / 14 15,000 23 / 21 / 18 12 24 / 22 / 15 21,000 25 / 23 / 17 100,000 PPM Conversion Table

Percent contamination vs. PPM (parts per million) Percent PPM 100% 1,000,000 10% 100,000 1% 10,000 0.1% 1,000 0.01% 100 0.001% 10

Volume

1 litre

= 1 000ml

1PPM

= 1µl in 1 litre

Example 1

400PPM in 1 litre

= 400µl

Example 2 A reading of 250PPM equates to a quantity of absorbed water in a 400 litre capacity system of 0.1 litre.

74

RISK ASSESSMENT FORM

KLEENOIL FILTRATION LTD: Fenton Lane,Sherburn In Elmet, LS25 5EZ

01977 682810 / sales@kleenoil.co.uk

Project Name:

Further assessments required:

Persons involved in or affected:

Individual Assessment req'd for: Nursing and Expectant Mothers Young Persons Disabled Service Users

Fire COSHH

Employees Visitors Contractors

KLEENOIL FILTER CHANGES AND OIL SAMPLING

Description of Work:

Manual Handling

To carry out filter changes on installed machine along with oil sampling to offer evaluation of oil condition

Display Screen Equipment Young Persons

Members of the public Others

Work Start Date:

Est Completion Date: 22/07/20

22/07/20

Key People / Groups in area 1. John Brough

2.

3.

Michael Cunningham

4.

5.

6.

Likelihood Without action

Grid Ref

Worst Case Outcome

Hazards Identified

Controls in Place

Additional Control Measures Required Score Rating

Working at Height - with risk of potentially Fatal falls, or bruising / fractures

All Jobs involving working at height discussed by staff (and contractor) and a safe system of work agreed before job begins Access equipment (eg ladders, tower scaffold ) kept in safe area and inspected prior to use

Minor Injury Likely

15 Low

Is a follow up assessment required? NO

Lara Layton Company Secretary

Completed by: Position: Signature:

Worst Case Outcome Likelihood

Score Guide

1 = No injury

1 = Remote

50 - 100 = High Risk

3 = Minor injury

2 = Unlikely

20 - 49 = Medium Risk

5 = Lost time injury

5 = Likely

1-19 = Low Risk

8 = Severe injury

8 = Very likely

10 = Fatality

10 = Certain / Imminent

Date of Assessment:

22/07/20

It’s important you understand this report. If you don’t you should seek proper Risk Assessment Training.

Page No: 1

RISK ASSESSMENT FORM

KLEENOIL FILTRATION LTD: Fenton Lane,Sherburn In Elmet, LS25 5EZ

01977 682810 / sales@kleenoil.co.uk

Likelihood Without action

Grid Ref

Worst Case Outcome

Hazards Identified

Controls in Place

Additional Control Measures Required Score Rating

All workers trained on Height equipment prior to use Refer to HSE guidance to ensure all necessary measures are being taken, see HSE web pages on falls from height www.hse.gove.uk/falls/machine.htm Ensure PAT tested equipment is used and staff have received training on tools

Electrical Tools Required to Carry out work with risk of potentially Fatal Shocks or Burns

Severe Injury Likely

40 Medium

Ensure Electrical Wires do not create trip hazard PPE to be supplied and used

Dust and off-cuts will be produced with possible slip / spillage

Carry out good housekeeping

Minor Injury Likely

15 Low

Offcuts to be cleared away promptly and dust cleared regularly Workers to wear strong Satety Shoes with Good Grip Remind staff to clear up spillages immediately, even if very minor

Noise from closeby equipment or other Tradesmen which can cause discomfort and potential damage

Shut down cause of noise

Minor Injury Likely

15 Low

Worst Case Outcome Likelihood

Score Guide

1 = No injury

1 = Remote

50 - 100 = High Risk

3 = Minor injury

2 = Unlikely

20 - 49 = Medium Risk

5 = Lost time injury

5 = Likely

1-19 = Low Risk

8 = Severe injury

8 = Very likely

10 = Fatality

10 = Certain / Imminent

It’s important you understand this report. If you don’t you should seek proper Risk Assessment Training.

Page No: 1

RISK ASSESSMENT FORM

KLEENOIL FILTRATION LTD: Fenton Lane,Sherburn In Elmet, LS25 5EZ

01977 682810 / sales@kleenoil.co.uk

Likelihood Without action

Grid Ref

Worst Case Outcome

Hazards Identified

Controls in Place

Additional Control Measures Required Score Rating

Wear Ear Defenders and use / maintain properly

Manual Handling - Materials will need to be carried to Work Area which if not done correctly can cause immediate or longer term injury

Ensure everybody involved has received Manual Handling training

Minor Injury Likely

15 Low

Use safety checked Trolly / Sack Truck Break Down Heavy Loads

Slips, Trips and Falls which can cause sprains, fractures etc if people fall over depris / offcuts / tools or slip on spillages

Protective non-slip footwear to be worn Minor Injury Likely

15 Low

Area to be tidied, cleaned and dry prior to work date Ensure walkways cleared of stock Take extra bins to tidy as we work at site to avoid further obstructions Display Appropriate Signage to make people aware of obstacle##Use Cordless Tools wherever possible Ensure worker checks in with customer and insists on regular checks from staff

Lone Working with risk of injury or ill health while working alone

Minor Injury Unlikely

6 Low

Make sure workers have method of contact

Worst Case Outcome Likelihood

Score Guide

1 = No injury

1 = Remote

50 - 100 = High Risk

3 = Minor injury

2 = Unlikely

20 - 49 = Medium Risk

5 = Lost time injury

5 = Likely

1-19 = Low Risk

8 = Severe injury

8 = Very likely

10 = Fatality

10 = Certain / Imminent

It’s important you understand this report. If you don’t you should seek proper Risk Assessment Training.

Page No: 4

RISK ASSESSMENT FORM

KLEENOIL FILTRATION LTD: Fenton Lane,Sherburn In Elmet, LS25 5EZ

01977 682810 / sales@kleenoil.co.uk

Likelihood Without action

Grid Ref

Worst Case Outcome

Hazards Identified

Controls in Place

Additional Control Measures Required Score Rating

No working at height

Worst Case Outcome Likelihood

Score Guide

1 = No injury

1 = Remote

50 - 100 = High Risk

3 = Minor injury

2 = Unlikely

20 - 49 = Medium Risk

5 = Lost time injury

5 = Likely

1-19 = Low Risk

8 = Severe injury

8 = Very likely

10 = Fatality

10 = Certain / Imminent

It’s important you understand this report. If you don’t you should seek proper Risk Assessment Training.

Page No: 6

Method Statement

Application - Customer –

cleaning oil tank and taking oil sample

APEX

Site contact –

Mark Wheeler

Date – 14/08/20 Work carried out by - John Brough Kleenoil

Overview

Kleenoil on site to position and connect MS Unit and use to clean tank of hydraulic oil All H&S processes to be completed prior to entering site. Ensure correct PPE is worn at all times. Ensure Covid19 Safety procedures are adhered to

Working Method

Clean tank using KLEENOIL MS unit

• Ensure unit is isolated electrically. • Position in safe place, ensure secure. • Install feed / return pipes according to access • allow pump to run for 10 minutes to check primed and running • continue to run and monitor cleanse • Complete cleanse • Turn off machine • Remove feed / return pipes • Check for leaks and spills and rectify where necessary • Clean area and ensure all hazards are removed.

Oil sampling

• Identify sample point from machine. • Insert sample hose and extract oil using handheld vacuum unit.

Clean area and dispose of all rubbish. Debrief all staff prior to leaving site.

Kleenoil Bypass Filtration Ltd Fenton Lane, Sherburn In Elmet, LS25 6EZ. www.kleenoil.co.uk Tel 01977 682810 Fax 01977 685457

Certificate of Registration QUALITY MANAGEMENT SYSTEM - ISO 9001:2015

Kleenoil Filtration Ltd Fenton Lane Sherburn in Elmet Leeds LS25 6EZ United Kingdom

This is to certify that:

Holds Certificate Number: FS 656474 and operates a Quality Management System which complies with the requirements of ISO 9001:2015 for the following scope:

Design, manufacture and supply of filter units, rigs and rig hire, for the specialist filtration of all mineral oils: oils and fuels, includes service, analysis and replacement cartridges.

For and on behalf of BSI:

Matt Page, Managing Director Assurance - UK & Ireland

Original Registration Date: 2016-10-10 Latest Revision Date: 2022-09-22

Effective Date: 2022-10-10 Expiry Date: 2025-10-09

Page: 1 of 1

This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract. An electronic certificate can be authenticated online. Printed copies can be validated at www.bsigroup.com/ClientDirectory Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 345 080 9000 BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK. A Member of the BSI Group of Companies.

Certificate of Employers' Liability Insurance (a)

(Where required by regulation 5 of the Employers' Liability (Compulsory Insurance) Regulations 1998 (the Regulations), one or more copies of this certificate must be displayed at each place of business at which the policy holder employs persons covered by this policy).

1. Policy number

SB28483370

2. Name of policy holder

Kleenoil Filtration Ltd and subsidiaries as lodged with Allianz

3. Date of commencement of insurance policy

05/11/2023

4. Date of expiry of insurance policy

05/11/2024

We hereby certify that subject to paragraph 2:- 1. the policy to which this certificate relates satisfies the requirements of the relevant law applicable in Great Britain, Northern Ireland, the Isle of Man, the Island of Jersey, the Island of Guernsey and the Island of Alderney (b); and

2. (a) the minimum amount of cover provided by this policy is no less than £5 million (c). (b) the cover provided under this policy relates to claims in excess of £

but not exceeding £

Signed on behalf of Allianz Insurance Plc

Authorised insurers

Simon McGinn Chief Executive Allianz Commercial

Notes (a) Where the employer is a company to which Regulation 3(2) of the regulations applies, the certificate shall state in a prominent place, either that the policy covers the holding company and all its subsidiaries, or that the policy covers the holding company and all subsidiaries except any specifically excluded by name, or that the policy covers the holding company and only the named subsidiaries. (b) Specify applicable law as provided for in regulation 4(6) of the Regulations. (c) See regulation 3(1) of the Regulations and delete whichever of paragraphs 2(a) or 2(b) does not apply. Where 2(b) is applicable, specify the amount of cover provided by the relevant policy.

Account number:

32/96676

Date printed:

01/11/2023

ACOM3211 09.11

Allianz Insurance Plc. Registered in England number 84638. Registered office: 57 Ladymead, Guildford, Surrey, GU1 1DB, United Kingdom. Allianz Insurance Plc is authorised by the Prudential Regulation Authority and regulated by the Financial Conduct Authority and the Prudential Regulation Authority. Financial Services Register number 121849.

ACOM3211 09.11

Park House Sandy Way Grange Park Northampton NN4 5EJ

T 01604 666777 E northampton.commercial@howdeninsurance.co.uk W howdenbroking.com

03 November 2023

Re: TO WHOM IT MAY CONCERN Kleenoil Filtration Ltd

We write to confirm that insurances for the above named company(ies) has been arranged on the following basis:

Summary Business Description

Manufacture and Installation of Secondary Oil Filters

Liability Insurance Policy

Insurer:

Allianz Insurance plc

Period of Insurance:

05/11/2023

to

04/11/2024

Policy Number:

SB/28483370

Limits of Liability:

Employers Liability (any one event)

£10,000,000

Public Liability (any one claim)

£10,000,000

Products Liability (any one period)

Separate Policy in Force

Insurer

M & M Underwriting Limited acting for AXA XL Insurance Company UK Limited

Period of Insurance

05/11/2023

to 04/112024

Policy Number:

MM002565

Limits of Liability:

Products Liability (any one period)

£10,000,000

This document is for information only. This document does not make the person or organisation to which it is issued an additional Insured, nor does it modify in any manner the contract of insurance between the Insured and the Underwriters. The aforementioned policy is subject to the insurers terms, conditions and exclusions. Should the above-mentioned contract (s) of insurance be cancelled, assigned or changed prior to or during the above policy period in such manner as to affect this document, no obligation to inform the holder of this document is accepted by the undersigned or by the Underwriters.

We trust that this is satisfactory, however, if we can be of further assistance please do not hesitate to contact us.

Yours faithfully

Associate Director For and on behalf of Howden UK Brokers Limited

Made with FlippingBook - Share PDF online