EMR SILVERTOWN - METSO

A X - Immediate Action C - Action B - Monitor A - No Action

EMR SILVERTOWN METSO SHEAR - EMR SILVERTOWN

Unit Number Serial Number

KLEENOIL FILTRATION LTD

Customer Name

HYDRAULICS UNKNOWN EMR SILVERTOWN

Make Model

Address

FENTON LANE,

Location

SHERBURN IN ELMET,WEST YORKSHIRE

Job No

30/04/2024

Sample Date

HYDRAULIC SYSTEM

Component Lubricant

Unknown 46

Received Date

08/05/2024

Ian Burton

Interpreted By

Reported Date

15/05/2024

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1

Previous #2

Lab No

- - - - - - - - -

- - - - - - - - -

541298138 30/04/2024

50

Sample Date

40

Meter Hrs Fluid Hrs Oil Added

0 0

30

0.00

V40

20

Fluid Changed Filter Changed

No No

10

Lubricant Label No

Unknown

0

-

Prev #3

Prev #2

Prev #1

Current

Physical Tests Viscosity at 40 C

Particles

ASTM D7279-14

cSt

43.4

28K

Water

ASTM D6304 ASTM D6304

ppm

74

24K

Water (% Wt) Oil Condition

% Wt.

0.0074

20K

16K

14 4 6 PQI

Total Acid Number

ASTM D8045

mg/g KOH

0.30

12K

Particles

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

137

8K

33

4K

2

0K

Prev #3

Prev #2

Prev #1

Current

4µ 6µ

2830

Oil Contaminants

954

32

70µ

0

28

ISO Code PQ Index

Code

19/17/14

24

In-House

N/A

33

20

Oil Contaminants

Na Si

16

Potassium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm

0

12

Silicon Sodium

25

8

0

4

Water

In-House

Pos/Neg

N

0

Wear Metals

Prev #3

Prev #2

Prev #1

Current

Aluminium Chromium

ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97

ppm ppm ppm ppm ppm ppm PPM ppm ppm ppm

0

0.0

Copper

0 0 0 0 0 0 0

Iron

Lead

Nickel Silver

0.0

Tin

Titanium Vanadium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

Made with FlippingBook - Share PDF online