Example oil report - trend
B X - Immediate Action C - Action B - Monitor A - No Action
UNKNOWN HYDRAULICS PLASTICS
Unit Number Serial Number
KLEENOIL FILTRATION LTD
Customer Name
Make Model
Address
SHERBURN IN ELMET,WEST YORKSHIRE FENTON LANE,
Location
13/11/2025
Sample Date
Job No
HYDRAULIC SYSTEM
Component Lubricant
Received Date
19/11/2025
Unknown 46
Ian Burton
Interpreted By
Reported Date
21/11/2025
Wear Metals
Wear Metals Vanadium
ASTM D5185-97
ppm
0
0
240
Additives Barium Boron Calcium
200
ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97
ppm ppm ppm ppm ppm ppm ppm
0 0
0 0
160
Cr Cu Fe Ni Pb
62
74
120
Magnesium Molybdenum Phosphorus
2 0
2 1
80
327 342
391 414
40
Zinc
0
Prev #1
Current
A - No Action B
Diagnosis: THE COPPER READING IS A LITTLE ELEVATED BUT OTHER WEAR READINGS GENERALLY GIVE US NO CAUSE FOR CONCERN. WE WILL OBSERVE THE NEXT SCHEDULED SAMPLE.
X - Immediate Action C - Action B - Monitor
Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.
Page 2 of 2
Made with FlippingBook Ebook Creator