Example oil report - trend

B X - Immediate Action C - Action B - Monitor A - No Action

Unit Number Serial Number

UNKNOWN HYDRAULICS PLASTICS

KLEENOIL FILTRATION LTD

Customer Name

Make Model

Address

SHERBURN IN ELMET,WEST YORKSHIRE FENTON LANE,

Location

13/11/2025

Sample Date

Job No

HYDRAULIC SYSTEM Unknown 46

Component Lubricant

Received Date Reported Date

19/11/2025

Interpreted By

21/11/2025

Physical Tests

Sample Details

Test Method

Units

Current Result

Previous #1 552138323 30/07/2025

Previous #2

Lab No

- - - - - - - - -

- - - - - - - - -

553238224 13/11/2025

60

Sample Date

50

Meter Hrs Fluid Hrs Oil Added

0 0

0 0

40

0.00

0.00

V40

30

Fluid Changed Filter Changed

No No

No No

20

10

Lubricant Label No

Unknown

Unknown

0

-

-

Prev #1

Current

Physical Tests Viscosity at 100 C Viscosity at 40 C

Particles

ASTM D7279-14 ASTM D7279-14

cSt cSt

8.4

8.2

14K

56.8 120 125

58.8 108 141

12K

Viscosity Index

ASTM D2270 ASTM D6304 ASTM D6304

Integer

10K

Water

ppm

8K

14 4 6 PQI

Water (% Wt) Oil Condition

% Wt.

0.0125

0.0141

6K

Total Acid Number

ASTM D8045

mg/g KOH

0.44

0.41

4K

Particles

2K

14µ 21µ 38µ

ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ISO 4406:2021 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 In-House

Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml Counts/ml

23

66 12

0K

Prev #1

Current

4 1

Oil Contaminants

1

6

4µ 6µ

3480

13388

735

2947

5

70µ

0

0

4

ISO Code PQ Index

Code

19/17/12

21/19/13

Na Si

3

N/A

4

9

Oil Contaminants

2

Potassium

ppm ppm ppm ppm ppm ppm ppm ppm ppm PPM ppm ppm

1 5 2

0 6 3

1

Silicon Sodium

0

Prev #1

Current

Wear Metals Aluminium

0

0

Chromium

0.2

0.1

Copper

176

231

Iron

9 1

10

Lead

2

Nickel Silver

0.0

0.0

0 0 0

0 0 0

Tin

Titanium

Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.

Page 1 of 2

Made with FlippingBook Ebook Creator