Report Example - plastics
C X - Immediate Action C - Action B - Monitor A - No Action
HYDRAULICS UNKNOWN TAYLOR ENG TAYLOR ENG NB1300T
Unit Number Serial Number
KLEENOIL FILTRATION LTD
Customer Name
Make Model
Address
FENTON LANE,
Location
SHERBURN IN ELMET,WEST YORKSHIRE
Job No
01/05/2025
Sample Date
HYDRAULIC SYSTEM Unknown unknown
Component Lubricant
Received Date
07/05/2025
Ian Burton
Interpreted By
Reported Date
14/05/2025
Wear Metals
Titanium Vanadium Additives
ASTM D5185-97 ASTM D5185-97
ppm ppm
0 0
Barium Boron Calcium
ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97 ASTM D5185-97
ppm ppm ppm ppm ppm ppm ppm
0 0
43
Magnesium Molybdenum Phosphorus
0 0
310 367
Zinc
A - No Action C
Diagnosis: ACTION REQUIRED! THE WEAR METALS GIVE US NO CAUSE FOR CONCERN AND THE WATER CONTENT IS ACCEPTABLE. HOWEVER, THE PARTICLE COUNT CANNOT BE MEASURED DUE TO THE AMOUNT OF DEBRIS IN THE SAMPLE. ASSUMING THIS IS A REPRESENTATIVE SAMPLE THEN FURTHER STEPS NEED TO BE TAKEN TO FIND THE SOURCE OF THE DEBRIS AND REMOVE THIS DEBRIS.
X - Immediate Action C - Action B - Monitor
Fluid and Condition Monitoring Services, Unit 3 Triangle Business Park, Oakwell Way, Birstall, Batley, West Yorkshire, WF17 9LU. Tel: 0113 201 2065 Email: Oillab@finning.co.uk. For more information, or to view your results online, please visit www.fluid-analysis.com This information is supplied for your benefit only and should not be relied on by any third party whatsoever.
Page 2 of 2
Made with FlippingBook. PDF to flipbook with ease