Report Example - plastics
FIL TR A TION S ITE V ISIT R EPORT
PLASTIC ENGINEERING
Injection Moulders – Oil Analysis Summary (with Kleenoil Bypass Filtration)
Machine References
NB1300T NB800T KM2700T 13E800T KM1300T NB2000T
•
•
•
•
•
•
1. Cleanliness Improvements (ISO Codes)
• Before Kleenoil: Several machines were too dirty to particle count, others ran at ISO 19 – 20/16 – 17/11 — high contamination levels that accelerate wear. • After Kleenoil: All now measure in the 17 – 18/14 – 15/9 – 11 range.
NB1300T: 17/15/10 NB800T: 17/14/9
o
o
o KM2700T: 20/16/11 (mid-size rise, but still acceptable)
13E800T: 19/17/11 KM1300T: 18/15/10 NB2000T: 18/15/10
o
o
o
Improvement: On average, a 2 – 3 class drop in particle contamination compared with pre installation, representing a 70 – 85% reduction in particle counts. Benefit: Lower abrasive wear, smoother hydraulic performance, extended pump/valve life.