SANDBACH COMMERCIAL DISMANTLERS
Extra notes
SANDBACH COMMERCIAL DISMANTLERS
EXCAVATOR CLEANSE
FEBRUARY 21
VOLVO
Has had water contamination
Have changed oil but due to it the numerous shafts, cylinders, pipes the water has blended back into the new oil. KLEENOIL were brought in on a day manned cleanse to remove the mois- ture and improve the oil.
KLEENOIL opted for the MS4 as although a small hydraulic tank – the obvious level of water con- tamination would require a few cartridge changes to remove such. An MS4 offers a flow rate on oil of aprx 1000 ltr per hr with a water retention capacity of 750ml per cartridge. The System includes the micromag MM10 to remove ferrous particulate. The 4 KLEENOIL SDU9788KU85 Remove all particulate down to 3 micron. And moisture.